Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e123181, dez 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1526439

ABSTRACT

Aim: To evaluate the effect of the exposure time and the type of composite in the production of radiographic artifact at the tooth / restorative interface. Materials and Methods: In 20 healthy bovine incisors, cavity preparations and class II restorations were made using composite resins Filtek Bulk Fill One (group 1) and Filtek Z350 (group 2). Then, the teeth were exposed to obtain digital radiographs, varying the exposure time by 0.07, 0.10, 0.14, 0.20 and 0.25s. The images were evaluated for investigation of the presence of artifact through the analysis of the modified number of pixels (QPXD) and the average gray value in class II (MGVR) restorations, using the Image J software (National Health Institute). Results: The presence of artifact was observed in all evaluated samples, regardless of the type of restorative material and the exposure time employed. There was no statistically significant difference in QPXD and MGVR between the resins used (ANOVA 2 factors, p p> 0.05). The MGVR analysis indicated that there were no statistically significant differences between resins or between exposure times (p> 0.05). There was a correlation between QPXD and MGVR (r = 0.29) for Filtek Bulk Fill One resin. Discussion: This study reveals the importance of attention to the region of the tooth-restoration interface by the Surgeon-Dentist, who must combine the radiographic findings diagnosed using digital tools to clinical signs in order to compose a unique therapeutic project with a real need for intervention, if there is such need. Conclusion: The presence of altered pixels on dentin in the region of the tooth-restoration interface was identified in all specimens. The variation in the exposure time as well as the type of the restorative composite did not influence the increase or decrease of QPXD and neither in MGVR. However, there was a correlation between QPXD and MGVR for Filtek Bulk Fill One resin.


Objetivo: Avaliar o efeito do tempo de exposição e do tipo de compósito na produção de artefato radiográfico na interface dente/material restaurador. Materiais e Métodos: Em 20 incisivos bovinos hígidos foram feitos preparos cavitários e restaurações classe II utilizando resinas compostas Filtek Bulk Fill One (grupo 1) e a Filtek Z350 (grupo 2). Em seguida, os dentes foram expostos para obtenção das radiografias digitais, variando o tempo de exposição em 0,07, 0,10, 0,14, 0,20 e 0,25s. As imagens foram avaliadas para investigação da presença de artefato através da análise do número de pixels modificado (QPXD) e do valor médio de cinza nas restaurações de classe II (MGVR), utilizando o software Image J (Instituto Nacional de Saúde, Bethesda, MD, EUA). Resultados: Observou-se a presença de artefato em toda amostra avaliada, independente de tipo de material restaurador e tempo de exposição empregado. Não se observou diferença estatisticamente significativa na QPXD e nos MGVR entre as resinas utilizadas (ANOVA 2 fatores, p p>0,05). A análise do MGVR indicou que não houve diferenças estatisticamente significativas entre as resinas nem entre os tempos de exposição (p>0,05). Observou-se uma correlação entre a QPXD e o MGVR (r=0,29) para a resina Filtek Bulk Fill One. Discussão: Como significado clínico, o presente estudo revela a importância da atenção à região da interface dente-restauração por parte do Cirurgião-Dentista, o qual deve aliar os achados radiográficos diagnosticados com o auxílio de ferramentas digitais aos sinais clínicos, para compor um projeto terapêutico singular com uma real necessidade de intervenção, caso haja. Conclusão: Foi identificado a presença de pixels alterados sobre a dentina na região da interface dente-restauração em todos os corpos de prova. A variação do tempo de exposição como também o tipo do compósito restaurador não influenciou no aumento ou diminuição do QPXD e nem tão pouco no MGVR. Contudo houve correlação entre o QPXD e o MGVR para a resina Filtek Bulk Fill One.

2.
Natal; s.n; 2020. 45 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1537309

ABSTRACT

Objetivo: Avaliar o efeito do tempo de exposição e do tipo de compósito na produção de artefato radiográfico na interface dente/material restaurador. Materiais e Métodos: Em 20 incisivos bovinos hígidos foram feitos preparos cavitários e restaurações classe II utilizando resinas compostas Filtek Bulk Fill One (gruo 1) e a Filtek Z350 (grupo 2). Em seguida, os dentes foram expostos para obtenção das radiografias digitais, variando o tempo de exposição em 0,07, 0,10, 0,14, 0,20 e 0,25s. As imagens foram avaliadas para investigação da presença de artefato através da análise do número de pixels modificado (QPXD) e do valor médio de cinza nas restaurações de classe II (MGVR), utilizando o software Image J (Instituto Nacional de Saúde, Bethesda, MD, EUA). Resultados: Observou-se a presença de artefato em toda amostra avaliada, independente de tipo de material restaurador e tempo de exposição empregado. Não se observou diferença estatisticamente significante na QPXD e nos MGVR entre as resinas utilizadas (ANOVA 2 fatores, p p>0,05). A análise do MGVR indicou que não houve diferenças estatisticamente significativas entre as resinas nem entre os tempos de exposição (p>0,05). Observou-se uma correlação entre a QPXD e o MGVR (r=0,29) para a resina Filtek Bulk Fill One. Conclusão: Foi identificado a presença de pixels alterados sobre a dentina na região da interface dente-restauração em todos os corpos de prova. A variação do tempo de exposição como também o tipo do compósito restaurador não influenciou no aumento ou diminuição do QPXD e nem tão pouco no MGVR. Contudo houve correlação entre o QPXD e o MGVR para a resina Filtek Bulk Fill One. Pesquisas adicionais são necessárias para determinar se o QPXD representa um artefato verdadeiro ou desajuste do material restaurador ou deficiência na aplicação sistema adesivo (AU).


Objective: To evaluate the effect of the exposure time and the type of composite in the production of radiographic artifact at the tooth / restorative interface. Materials and Methods: In 20 healthy bovine incisors, cavity preparations and class II restorations were made using composite resins Filtek Bulk Fill One (group 1) and Filtek Z350 (group 2). Then, the teeth were exposed to obtain digital radiographs, varying the exposure time by 0.07, 0.10, 0.14, 0.20 and 0.25s. The images were evaluated for investigation of the presence of artifact through the analysis of the modified number of pixels (QPXD) and the average gray value in class II (MGVR) restorations, using the Image J software (National Health Institute). Results: The presence of artifact was observed in all evaluated samples, regardless of the type of restorative material and the exposure time employed. There was no statistically significant difference in QPXD and MGVR between the resins used (ANOVA 2 factors, p p> 0.05). The MGVR analysis indicated that there were no statistically significant differences between resins or between exposure times (p> 0.05). There was a correlation between QPXD and MGVR (r = 0.29) for Filtek Bulk Fill One resin. Conclusion: The presence of altered pixels on dentin in the region of the tooth-restoration interface was identified in all specimens. The variation in the exposure time as well as the type of the restorative composite did not influence the increase or decrease of QPXD and neither in MGVR. However, there was a correlation between QPXD and MGVR for Filtek Bulk Fill One resin. Further research is needed to determine whether QPXD represents a true artifact or misfit of the restorative material or deficiency in the adhesive system application (AU).


Subject(s)
Animals , Cattle , Artifacts , Composite Resins/chemistry , Radiography, Dental, Digital/instrumentation , Incisor , In Vitro Techniques/methods , Analysis of Variance
3.
Conscientiae saúde (Impr.) ; 16(2): 2017194200, jun. 2017.
Article in Portuguese | LILACS | ID: biblio-875781

ABSTRACT

Introdução: A radiofrequência é um recurso que têm sido frequentemente utilizados na prática clínica para o tratamento da flacidez facial e aparecimento de rugas. Objetivo: Investigar os efeitos da radiofrequência no rejuvenescimento facial. Métodos: Trata-se de um ensaio clínico controlado. A amostra foi composta por 40 voluntárias do sexo feminino, com a faixa etária entre 35 a 55 anos, dispostos em 02 grupos, sendo grupo controle e grupo tratado com radiofrequência. Resultados: Nos valores individuais das medidas do ângulo do sulco nasogeniano é possível verificar um aumento e consequente melhora da qualitativa da flacidez facial. Conclusão: A radiofrequência promoveu uma melhora clínica ao nível do ângulo do sulco nasogeniano. (AU)


Introduction: Radiofrequency is a feature that has been frequently used in clinical practice for the treatment of facial flaccidity and appearance of wrinkles. Objective: To investigate the effects of radiofrequency on facial rejuvenation. Methods: This is a controlled clinical trial. The sample consisted of 40 female volunteers, with the age group between 35 and 55 years, arranged in 02 groups, being the control group and the group treated with radiofrequency. The control conducted 2 months of guidance on skin care and exercises for facial flaccidity. Results: Increase quality improvement of facial flaccidity In the treated group, but statistically there was no result in the comparison between groups. Conclusion: In the qualitative analysis, it was verified that the radiofrequency promoted a clinical improvement at the angle of the nasogenian sulcus. (AU)


Subject(s)
Humans , Female , Adult , Middle Aged , Nasolabial Fold , Radiofrequency Therapy , Aesthetic Equipment
4.
Rev. bras. geriatr. gerontol ; 18(4): 725-734, Oct.-Dec. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-770469

ABSTRACT

Objective : To evaluate the facial aging of women of different ages using a software program to assist in the classification of wrinkles and sagging in the nasogenian region. Method : A descriptive observational study of 100 female volunteers was performed. The women were aged between 20 and 70 years old and were sorted by age group into five groups of 20 volunteers each. The instruments used were the Facial Assessment Protocol, a cephalostat for the standardization of photos, a 14.1 megapixel Sony digital camera, and the Radiocef 2.0® software program. The Kolmogorov-Smirnov (KS) test was used for confirmation of normality and all data was statistically analyzed using ANOVA and Tukey's post hoc analysis. The Chi-squared and Pearson's correlation tests were also performed. A significance level of 5% and a p value of ≤0.05 were adopted. Results : It was observed that all age groups had wrinkles in the nasolabial fold region. There was an association between age and the Goglau, Lapiere and Pierard scale. This incidence increased progressively with aging. A moderate correlation (r=0.67) was observed between age and distance from the nasolabial folds, while angle represented only a weak correlation (r=0.3), with the most significant age group that with the shortest distance and the widest angle. Conclusion : The present study demonstrated the importance of the Radiocef 2.0® software program in providing a more detailed analysis of the nasolabial folds. It is therefore a complementary assessment to the Facial Assessment Protocol, representing a research protocol for identifying the effectiveness of treatments and improving the evaluative procedure.


Objetivo : Analisar a relevância da mensuração objetiva de rítides nasogenianas de mulheres em diferentes faixas etárias, utilizando-se osoftware radiocef 2.0® como ferramenta complementar na avaliação do cronoenvelhecimento facial. Método: Trata-se de um estudo observacional descritivo envolvendo 100 voluntárias do sexo feminino, com idade entre 20 e 70 anos, dispostas em cinco grupos de 20 voluntárias de acordo com a faixa etária. Os instrumentos utilizados foram o Protocolo de Avaliação Facial, o cefalostato para padronização das fotos, câmera digital e o software radiocef 2.0®. Foi aplicado o teste Kolmogorov-Smirnov para a confirmação da normalidade e todos os dados foram submetidos à análise estatística, usando o teste ANOVA e post hoc de Tukey. Foi realizado o teste Qui-quadrado e a correlação de Pearson. Foi adotado um nível de significância de 5% (p≤0,05). Resultados : Foi observado que todas as faixas etárias apresentaram rugas na localização do sulco nasogeniano. Observou-se também uma associação entre a idade e as escalas de Goglau e Lapiere e Pierard. Essa incidência surgiu progressivamente com o aumento da faixa etária. Foi verificada correlação moderada (r=0,67) entre a idade e a distância do sulco nasogeniano, enquanto o seu ângulo diminui com correlação fraca (r=0,3), sendo mais significativa a faixa etária que obteve a menor distância e o maior ângulo. Conclusão: O estudo demonstrou relevância do software radiocef 2.0®. para a análise mais detalhada do sulco nasogeniano, surgindo assim como uma complementação da avaliação, podendo se tornar um protocolo de investigação para identificar a eficácia dos tratamentos realizados, otimizando o método avaliativo.

SELECTION OF CITATIONS
SEARCH DETAIL